100G SFP-DD to SFP-DD Direct Attached Cable
Absolute Maximum Ratings
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
Supply Voltage |
Vcc |
3. 13 |
3.3 |
3.47 |
V |
Storage temperature |
Ts |
-40 |
|
85 |
ºC |
Operating Case temperature |
Tc |
0 |
|
70 |
ºC |
Humidity |
Rh |
5 |
|
85 |
% |
DataRate |
|
|
100 |
|
Gbps |
Physical Characteristics
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
Length |
L |
0.5 |
|
3 |
M |
AWG |
|
30 |
|
26 |
AWG |
Jacket material |
|
PVC, Black |
|||
Flame Rating |
|
VW- 1 |
Electrical Specifications
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
Resistance |
Rcon |
|
|
3 |
ohm |
Insulation Resistance |
Rins |
|
|
10 |
ºC |
Raw cable impedance |
Zca |
95 |
|
110 |
Mohm |
Mated connector Impedance |
Zmated |
85 |
|
110 |
ohm |
Maximum insertion loss at 13.28 GHz |
SDD21 |
|
|
17. 16 |
dB |
Other SI Performance |
|
Comply with IEEE802.3cd&bj |
|||
Minimum COM |
COM |
3 |
|
|
dB |
Pin Description
Figure 1. Electrical Pin-out Details for SFP-DD
Table 1-Pad Function Definition
Pad |
Logic |
Symbol |
Module pad Descriptions |
Plug sequence |
Notes |
1 |
|
GND |
Ground |
1A |
1 |
2 |
LVTTL-O |
Tx Fault0 |
Transmitter Fault Indication for channel 0 |
3A |
|
3 |
LVTTL-I |
Tx Disable0 |
Transmitter Disable for channel 0 |
3A |
|
4 |
LVCMOS-I/O |
SDA |
Management I/F data line |
3A |
|
5 |
LVCMOS-I/O |
SCL |
Management I/F clock |
3A |
|
6 |
LVTTL-O |
ModABS |
Module Absent |
3A |
|
7 |
LVTTL-I |
Speed0-1 |
Rx Rate Select for channel 0 |
3A |
|
8 |
LVTTL-O |
Rx LOS0 |
Rx Loos of Signal for channel 0 |
3A |
|
9 |
LVTTL-I |
Speed0-2 |
Tx Rate Select for channel 0 |
3A |
|
10 |
|
GND |
Ground |
1A |
1 |
11 |
|
GND |
Ground |
1A |
1 |
12 |
CML-O |
RDO- |
Inverse Received Data Out for channel 0 |
3A |
|
13 |
CML-O |
RD0+ |
Received Data Out for channel 0 |
3A |
|
14 |
|
GND |
Ground |
1A |
1 |
15 |
|
Vcc R0 |
Receiver power |
2A |
2 |
16 |
|
Vcc TO |
Transmitter power |
2A |
2 |
17 |
|
GND |
Ground |
1A |
|
18 |
CML-I |
TDD+ |
Transmit Data li for channel 0 |
3A |
|
19 |
CML-I |
TDD- |
Inverse Transmit Data In for channel 0 |
3A |
|
20 |
|
GND |
Ground |
1A |
1 |
21 |
|
GND |
Ground |
1B |
1 |
22 |
LVTTL-O |
Tx Fault1 |
Transmitter Fault Indication/Interrupt for channel 1 |
3B |
|
23 |
LVTTL-O |
TxDisable1 |
Transmitter Disable for channel 1 |
3B |
|
24 |
|
Reserved |
Reserved for future Use |
3B |
|
25 |
LVTTL-I |
LP Mode |
Low Power Mode Control |
3B |
|
26 |
|
Reserved |
Reserved for future Use |
3B |
3 |
27 |
LVTTL-I |
Speed1-1 |
Rx Rate Select for channel 1 |
3B |
|
28 |
LVTTL-O |
Rx LOS1 |
Loss of signal for channel 1 |
3B |
|
29 |
LVTTL-I |
Speed1-2 |
Tx Rate Select for channel 1 |
3B |
|
30 |
|
GND |
Ground |
1B |
1 |
31 |
|
GND |
Ground |
1B |
1 |
32 |
CML-O |
RD1 |
Inverse Received Data Out for channel 1 |
3B |
|
33 |
CML-O |
RD1+ |
Received Data Out for channel 1 |
3B |
|
34 |
|
GND |
Ground |
1B |
1 |
35 |
|
VccR1 |
Received Power for channel 1 |
2B |
2 |
36 |
|
VccT1 |
Transmitter Power for channel 1 |
2B |
2 |
37 |
|
GND |
Ground |
1B |
1 |
38 |
CML-I |
TD1+ |
Transmitter Data in for channel 1 |
3B |
|
39 |
CML-I |
TD1- |
Inverse Transmit Data Out for channel 1 |
3B |
|
40 |
|
GND |
Ground |
1B |
1 |
Mechanical Dimensions
Ordering Information
Part No. |
Description |
SFPDD-100G-005 |
100GSFP-DDtoSFP-DDDAC,30AWG, 0.5m,PVC,BLACK. |
SFPDD-100G-010 |
100GSFP-DDtoSFP-DDDAC,30AWG, 1.0m,PVC,BLACK. |
SFPDD-100G-015 |
100GSFP-DDtoSFP-DDDAC,30AWG, 1.5m,PVC,BLACK. |
SFPDD-100G-020 |
100GSFP-DDtoSFP-DDDAC,30AWG, 2.0m,PVC,BLACK. |
SFPDD-100G-025 |
100GSFP-DDtoSFP-DDDAC,26AWG,2.5m,PVC,BLACK. |
SFPDD-100G-030 |
100GSFP-DDtoSFP-DDDAC,26AWG, 3.0m,PVC,BLACK. |
References
1. SFP-DD MSA Rev2. 1
2. IEEE802.3cd&802.3bj
3. SFP-DD-MIS-Rev2.0